15.3
Configuring SNMP (CLI)
P-20C, IP-20S, and IP-20E support SNMP v1, V2c, and v3. You can set
community strings for access to IP-20 units.
IP-20C, IP-20S, and IP-20E support the following MIBs:
RFC-1213 (MIB II).
RMON MIB.
Proprietary MIB.
Access to the unit is provided by making use of the community and context
fields in SNMPv1 and SNMPv2c/SNMPv3, respectively.
This section includes:
Configuring Basic SNMP Settings (CLI)
Displaying the SNMP Settings (CLI)
Configuring Trap Managers (CLI)
15.3.1
Configuring Basic SNMP Settings (CLI)
To enable SNMP, enter the following command in root view:
root> platform security protocols-control snmp admin set
<admin>
To specify the SNMP version, enter the following command in root view:
root> platform security protocols-control snmp version set
<version>
To specify the SNMP read and write communities, enter the following
command in root view:
root> platform security protocols-control snmpv1v2 set read-
community <read-community> write-community <write-community>
Table 84: Basic SNMP CLI Parameters
Parameter
Input Type
Permitted Values
Description
admin
Variable
enable
disable
Select enable to enable SNMP
monitoring, or disable to disable
SNMP monitoring.
version
Variable
v1
v2
v3
Specifies the SNMP version.
read-
community
Text String
Any valid SNMP read
community.
The community string for the SNMP
read community.
write-
community
Text String
Any valid SNMP write
community.
The community string for the SNMP
write community.