FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 587 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
5002
g8032-failure-of-
protocol-pm-alarm
Alarm
More than a single RPL is configured
in a ring
Warning
User configuration
Reconfigure the RPL
5003
lldp-topology-change
Event
LLDP topology change
Warning
New neighbor
None
5004
security-log-upload-
started-event
Event
Security log upload started
Indeterminate Security log upload started
5005
security-log-upload-
failed-event
Event
Security log upload failed
Indeterminate Security log upload failed
5006
security-log-upload-
succeeded-event
Event
Security log upload succeeded
Indeterminate Security log upload succeeded
5010
force-mode-alarm
Alarm
System is in sync force mode state
Warning
User command
5011
sync-quality-change-
event
Event
The sync-source quality level was
changed
Major
5012
system-clock-in-
holdover-mode
Alarm
System Synchronization Reference in
Holdover Mode
Critical
5013
sync-T0-quality-change-
event
Event
The system's reference-quality
changed
Major
5014
sync-pipe-invalid-
interface-clock-source
Alarm
The pipe interface clock-source in
signal-interface table is not system-
clock
Major
5015
sync-pipe-missing-edge Alarm
The pipe is missing an edge interface Major
Regenerator contains less than 2
interfaces
Accomplish configuration by assigning
second interface
5016
sync-pipe-interface-op-
state-down
Alarm
Pipe interface operational state is
down
Major
At least one of Regenerator Interfaces
status is down
Checking regenerator Admin status