3 In the Protection Admin field, select Enable.
4 Click Apply.
The system configures itself for HSB protection:
The system determines which unit is the Active unit based on a number of
pre-defined criteria.
When the system returns online, all management must be performed via
the Active unit using the IP address you defined for that unit.
The IP address you defined for the unit which is now the Standby unit is no
longer valid, and the management port of the Standby unit becomes non-
operational.
Management of the Standby unit is performed via the Active unit, via the
cable between the two MIMO/Prot ports on the splitters connecting the
two units.
The Unit Redundancy page refreshes to include additional radio protection
fields.