Figure 109: Aggregate PM Report Page
2 For the IP-20C, in the Port field, select the port that holds the radio for
which you want to display PMs.
3 In the Interval Type field:
To display reports in 15-minute intervals, select 15 minutes.
To display reports in daily intervals, select 24 hours.
Table 29 describes the Modem BER (Aggregate) PMs.
Note:
To display the same parameters for a specific interval in a
separate page, select the interval in the Modem BER PM
table and click View.
Table 29: Modem BER (Aggregate) PMs
Parameter
Definition
Interval
For 24-hour intervals, displays the date of the interval. For 15-minute
intervals, displays the date and ending time of the interval.
ES
Displays the number of seconds in the measuring interval during which
errors occurred.
SES
Displays the number of severe error seconds in the measuring interval.
UAS
Displays the Unavailable Seconds value of the measured interval. The value
can be between 0 and 900 seconds (15 minutes).