FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 575 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1602
lock-detect
Alarm
IF synthesizer is unlocked.
Critical
1.
Extreme temperature condition.
2.
HW failure.
1.
Check installation.
2.
Reset the RMC (Radio Modem
Card) module.
3.
Replace the RMC (Radio Modem
Card).
1701
cable-open
Alarm
Cable open
Major
Cable is not connected to RMC (Radio
Modem Card) or RFU
1.
Check IF cable and connectors.
2.
Verify that the N-Type connector
inner pin is not spliced.
3.
Replace RMC (Radio Modem
Card).
4.
Replace RFU.
1702
cable-short
Alarm
Cable short
Major
Physical short at the IF cable
1.
Check IF cable and connectors.
2.
Verify that the N-Type connector
inner pin is not spliced.
3.
Replace RMC (Radio Modem
Card).
4.