FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 570 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
601
radio-excessive-ber
Alarm
Radio excessive BER
Major
1.
Fade in the link.
2.
Defective IF cable.
3.
Fault in RFU.
4.
Fault in RMC (Radio Modem
Card).
1.
Check link performance.
2.
Check IF cable and replace if
required.
3.
Replace RFU.
4.
Replace RMC (Radio Modem
Card).
602
remote-link-id-mismatch Alarm
Link ID mismatch
Major
Link ID is not the same at both sides of
link
Configure same Link ID for both sides of
link
603
radio-lof
Alarm
Radio loss of frame
Critical
1.
Fade in the link.
2.
Defective IF cable.
3.
Fault in RFU.
4.
Fault in RMC (Radio Modem
Card).
5.
Different radio scripts at both
ends of the link.
1.
Check link performance.
2.
Check IF cable and replace if
required.
3.
Replace RFU.
4.
Replace RMC (Radio Modem
Card).
5.
Make sure same script is loaded at
both ends of the link.
604
radio-signal-degrade
Alarm
Radio signal degrade
Minor
1.
Fade in the link.
2.
Defective IF cable.
3.
Fault in RFU.
4.
Fault in RMC (Radio Modem
Card).
1.
Check link performance.
2.
Check IF cable and replace if
required.
3.
Replace RFU.
4.
Replace RMC (Radio Modem
Card).
605
radio-link-up
Event
Radio interface is up
Warning
606
radio-link-down
Event
Radio interface is down
Warning