Table 43: Ethernet RX Port PMs
Parameter
Definition
Interval
For 24-hour intervals, displays the date of the interval. For 15-minute intervals,
displays the date and ending time of the interval.
Peak... Average... bytes...
Packets...
Various peak transmission rates (in seconds) and average RX rates (in seconds),
both in bytes and in packets, for each measured time interval.
RX bytes Layer 1 exceed
threshold (sec)
The number of seconds the RX bytes exceeded the specified threshold during the
interval. For instructions on setting the threshold, see Setting the Ethernet Port RX
Threshold.
Invalid data flag
Indicates whether the values received during the measured interval are valid. An x
in the column indicates that the values are not valid (for example, because of a
power surge or power failure that occurred during the interval).
To clear the PMs, click Clear All.
6.5.3.2 Enabling or Disabling Gathering of Port RX PM Statistics per Interface
To select the interfaces for which to gather and display Port RX PMs:
1 In the Ethernet Port RX PM Report page, click PM Admin. The Ethernet PM
Port Admin page opens.
Figure 137: Ethernet PM Port Admin Page
2 Select the interface.
3 Click Enable Port PM or Disable Port PM to enable or disable the
gathering of Port RX PMs on the selected interface.