FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 568 of 597
24.
Alarms List
The following table lists all alarms used in the IP-20C/S/E products.
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
10
radio-digital-loopback
Alarm
Framer digital loopback
Warning
User enabled framer digital loopback. Disable framer digital loopback.
25
main-board-extreme-
temperature-alarm
Alarm
Unit Temperature is out of system
specified limits.
Warning
28
main-board-warm-reset Event
Unit warm reset.
Indeterminate
29
main-board-cold-reset
Event
Unit reset.
Warning
30
main-board-poe-low-
voltage-alarm
Alarm
POE input voltage is too low
Warning
31
Event
Change Remote request was sent
Major
(1)
32
Event
Protection switchover due to remote
request
Major
(1)
33
protection-mimo-
misconfiguration-alarm
Alarm
Major
Unit Redundancy and MIMO 4x4
cannot operate simultaneously.
(2)
100
lag-degraded
Alarm
LAG is not fully functional - LAG
Degraded.
Major
101
lag-down
Alarm
LAG operational state is down
Critical
102
ethernet-loopback-
active-alarm
Alarm
Loopback is active
Major
Ethernet loopback is active.
Wait till loopback timeout expires or
disable loopback.