Note:
You can use the following CLI command to display a list of
mismatched parameters:
root> platform management protection show
mismatch details
3.6.3
Configuring 2+2 HSB Protection on an IP-20C Unit
In order to configure 2+2 HSB unit protection on an IP-20C unit, you must
simply enable the second radio carrier on both units on both sides of the link.
No other configuration is necessary other than the configuration described
above.
To enable the second radio carrier on both units, use the Interface
Manager page (see Figure 13). The following figure shows the Interface
Manager page with both radio carriers enabled.
Figure 56: Interface Manager Page
– Both Radio Carriers Enabled
3.6.4
Viewing the Configuration of the Standby unit
You can view the settings of the standby unit any time.
To view the settings of the standby unit, click the Standby tab of the desired
page. The following is an example of the Standby tab of the Radio Parameters
page after Protection Admin has been enabled.
Figure 57: Standby Tab of Radio Parameters Page