FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 579 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1734
tx-level-out-of-range
Alarm
RFU TX level out of range
Minor
Defective RFU (the RFU cannot
transmit the requested TX power)
1.
Replace RFU.
2.
Intermediate solution - reduce TX
power.
1735
tx-mute
Alarm
RFU TX Mute
Warning
RFU Transmitter muted by user
Unmute the RFU transmitter
1736
unknown-rfu-type
Alarm
IDU SW does not support this type of
RFU
Major
IDC SW does not support the RFU
Upgrade IDC SW
1769
unit-cold-reset-event
Event
Unit Perform Power up
Warning
1770
cable-lof-rfu
Event
Unit performing power-up.
Major
1771
cable-error-rfu
Alarm
RFU cable error.
Major
Errors in signal from IDU to XCVR.
1.
Check the IF cable and connectors.
2.
Verify that the N-Type/TNC
connector inner pin is not spliced.
3.
Replace RMC.
4.
Replace XCVR.
1772
xpic-data-los
Alarm
Radio XPIC sync loss
Major
Signaling between RMCs (Radio
Modem Cards) for XPIC functionality
has failed
1.
Check that the RMCs are in
allowed slots.
2.
Populate the RMCs in different
allowed location in the chassis.
3.
Replace RMC/s.
4.
Replace chassis.