Page 588 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
5017
sync-pipe-invalid-pipe
Alarm
Pipe is invalid
Major
Interfaces has Configuration or
Operation fails
Configuration not accomplished
5030
soam-connectivity-
failure
Alarm
A connectivity failure in MA/MEG
Minor
Specific defect dependent: User
configuration , connectivity loss.
Reconfigure the RPL.
5100
mkey-mismatch
Alarm
Master key mismatch cross over the
link
Critical
Master Key was not set correctly.
Verify the Master Key.
(1)
5101
mkey-no-exist
Alarm
No Master Key set, default value
used
Warning
Crypto module has been enabled, but
no Master Key has been loaded.
Set the Master Key.
(1)
5102
general-encryption-
failure
Alarm
Payload Encryption failure
Critical
1.
Radio LOF on Tx/Rx direction.
2.
The session key does not match
across the link.
1.
The AES admin setting does not
match across the link.
1.
Validate the MSE on both sides of
the link.
2.
Validate the session key on both
sides of the link.
1.
Validate the AES admin setting on
both sides of the link.
(1)
5103
kep-finished
Event
Key Exchange Protocol successfully
finished
Indeterminate
(1)
5104
kep-initiated
Event
Key Exchange Protocol initiated
Indeterminate
(1)
5105
kep-remote-initiated
Event
Key Exchange Protocol initiated by
remote side
Indeterminate
(1)
5106
kep-zeroized
Event
Key Zeroization command executed Indeterminate
(1)
5107
bypass-self-test-alarm
Alarm
FIPS Bypass Self-Test failed
Critical
Disk failure
(1)
5108
post-fail-alarm
Alarm
Power On Self-Test Failed
Critical
System failure
Reboot the unit.