FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 574 of 597
Alarm ID Name
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1165
cli-script-activation-
failure
Event
CLI Configuration script failed
Warning
1.
Syntax Error.
2.
Error returned by system during
runtime
Verify script in the relevant line, and run
again.
Note that script may assume pre-
existing configuration.
1166
unit-info-file-transfer-
status-changed
Event
Unit info file transfer status:
Warning
1167
unit-info-file-creation-
status-changed
Event
Unit info file creation status:
Warning
1169
restore-started
Event
Configuration restore operation
started
Warning
Restore operation started because of
user command
1201
file-missed
Alarm
Modem firmware file not found
Critical
Modem file is missing
1.
Download software package.
2.
Reset the system.
1202
load-failed
Alarm
Modem firmware was not loaded
successfully
Critical
1.
Modem firmware file is corrupted.
2.
System failure.
1.
Download software package.
2.
Reset the system.
1203
modem-wd-reset
Event
Modem watch-dog reset event
Warning
1312
script-loading-failed
Alarm
Radio MRMC script loading failed
Major
Damaged hardware module
Replace the radio hardware module
1401
incompatible-rfu-tx-
calibration
Alarm
Incompatible RFU TX calibration
Major
RFU calibration tables require SW
upgrade
Upgrade IDU SW
1501
remote-communication-
failure
Alarm
Remote communication failure
Critical
Fade in the link
Check the link performance
1601
if-loopback
Alarm
IF loopback
Warning
User enabled IF loopback
Disable IF loopback