![Rohde & Schwarz 1145.1010.04/05/06 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/rohde-and-schwarz/1145-1010-04-05-06/1145-1010-04-05-06_operating-manual_1477759059.webp)
R&S
®
ZVB
Putting the Instrument into Operation
1145.1055.62 1.11
E-2
Instrument Setup
The network analyzer is designed for use under laboratory conditions, either on a bench top or in a
rack. The general ambient conditions required at the operating site are as follows:
•
The ambient temperature must be in the ranges specified for operation and for compliance with
specifications (see data sheet).
•
All fan openings including the rear panel perforations must be unobstructed. The distance to the
wall should be at least 10 cm.
Attention!
To avoid damage of electronic components of the DUT and the analyzer, the
operating site must be protected against electrostatic discharge (ESD). ESD is
most likely to occur when you connect or disconnect a DUT or test fixture to the
analyzer's test ports.
To prevent ESD damage use the wrist strap and grounding cord supplied with
the instrument and connect yourself to the GND connector at the front panel.
Bench Top Operation
If the analyzer is operated on a bench top, the surface should be flat.
The instrument can be used in horizontal position, standing on its feet, or with the support feet on the
bottom extended.
Attention!
The feet must be fully folded in or out. Only in this way can the stability of analyzer
be guaranteed and reliable operation be ensured.
The total weight on the extended feet (including the analyzer's weight and other
units placed on top) must not exceed 500 N. The units must be secured against
slipping (e.g. by locking the feet at the upper front frame).
When moving the unit with expanded feet, the feet might collapse and fold in. To
avoid injuries, the unit must therefore not be moved with the feet out.
Содержание 1145.1010.04/05/06
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ...Contents of Chapter 1 R S ZVA 1145 1090 62 I 1 2 E 1 Windows XP Embedded 1 22 Firmware Update 1 22...
Страница 48: ......
Страница 70: ......
Страница 72: ......
Страница 90: ......
Страница 92: ......
Страница 108: ......
Страница 156: ......
Страница 162: ......
Страница 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Страница 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Страница 462: ......
Страница 766: ......
Страница 772: ......
Страница 792: ......
Страница 794: ......
Страница 808: ......