R&S
®
ZVA/ZVB/ZVT
Channel
Menu
1145.1084.12 4.215
E-6
Generators
(Gen 1, Gen 2, ...)
must be configured explicitly in the
System Configuration
–
External Generators
dialog
before they appear in the list. Behind the source, a message
indicates the status of the power calibration.
•
Take Cal Sweep
initiates a calibration sweep for the selected wave quantity and source. The
progress of the sweep is monitored in the
Sweep
progress bar.
•
Abort Sweep
stops a running sweep. The data acquired in the aborted sweep is discarded.
The accuracy of the receiver power calibration depends on the accuracy of the source.
Depending on the test setup and reference plane, it is recommendable to perform a source
power calibration before the receiver power calibration.
Remote control:
[SENSe<Ch>:]CORRection:POWer:ACQuire
[SENSe<Ch>:]CORRection:POWer:AWAVe[:STATe]
[SENSe<Ch>:]CORRection:POWer:DATA
[SENSe<Ch>:]CORRection:POWer[:STATe]
Status Messages for Power Calibration
The status of a power calibration is indicated in the trace list and in the
Used Source
panel of the
Receiver Power Cal
dialog. The following messages can be displayed:
•
PCal
denotes an active power calibration with unchanged sweep points (no interpolation or
extrapolation).
•
PCai
denotes an active, interpolated power calibration (at least one calibration step is
interpolated).
•
PCa?
denotes an active power calibration with changed step attenuator setting and disabled
ALC.
•
PCao
denotes an active power calibration with a changed source power (in at least one
calibration step).
•
PCax
denotes an active, extrapolated power calibration (in at least one calibration step).
•
Uncal
denotes an uncalibrated source (not available for traces).
The labels appear in the trace list, provided that the measured quantity is an S-Parameter, wave
quantity, ratio, or a derived quantity (stability factor, PAE), and that the necessary calibrations have
been performed.
Necessary Calibrations
A trace is marked as power calibrated as soon as the analyzer assumes that the effects of an
inaccurate source or receiver power have been consistently removed. The conditions for consistency
depend on the measured quantity (see also
Data Flow)
:
•
S-parameters S
xy
represent the ratio of a received wave b
x
to a driving wave a
y
. The system
error correction for S-parameters generally includes a receiver power calibration, however, a
source power calibration can still improve the accuracy. Therefore S-parameters are assumed
to be power calibrated as soon as the driving wave has been power calibrated. The same holds
for quantities derived from S-parameters, e.g. stability factors.
•
For wave quantities, ratios, and derived quantities (e.g. the PAE), the driving waves and all
receivers must be power calibrated.
Содержание 1145.1010.04/05/06
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ...Contents of Chapter 1 R S ZVA 1145 1090 62 I 1 2 E 1 Windows XP Embedded 1 22 Firmware Update 1 22...
Страница 48: ......
Страница 70: ......
Страница 72: ......
Страница 90: ......
Страница 92: ......
Страница 108: ......
Страница 156: ......
Страница 162: ......
Страница 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Страница 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Страница 462: ......
Страница 766: ......
Страница 772: ......
Страница 792: ......
Страница 794: ......
Страница 808: ......