list) of the wave that forms the
numerator of the ratio.
The input (stimulus) or output
(response) port number is selected in the right pull-down list. The range of output and input port
numbers depends on the analyzer model.
•
Denominator
selects the type (left pull-down list) and the port number assignment (right pull-
down list) of the wave that forms the denominator of the ratio. The same waves as for the
Numerator
are available.
•
Ratio
indicates the selected ratio.
•
Source Port
selects one of the available test ports of the analyzer as a source of the stimulus
signal.
•
Detector
selects the algorithm that is used to calculate the displayed trace from the individual
measurement points. In the
Max.
and
RMS
detector modes, it is possible to define the detector
observation time
(Meas. Time)
for a single measurement point. Detector settings are available
for ZVA and ZVT network analyzers only.
Remote
control:
CALCulate<Ch>:PARameter:MEASure "<Trace_Name>", "B2/A1" | ...
[SENSe<Ch/Tr>:]FUNCtion[:ON] "...POWer:RATIO B2, A1"
etc.
Create new trace and select name and measurement parameter:
CALCulate<Ch>:PARameter:SDEFine "<Trace_Name>", "B2/A1" | ...
Detector
Selects the algorithm that is used to calculate the displayed measurement points from the raw data. The
Detector
can be selected in the
More Ratios
and
More Wave Quantities
dialogs. Detector settings are
available for ZVA and ZVT network analyzers only.
The following detectors are available:
•
Normal
selects the default detector mode where each measurement point is displayed without
modification as soon as it is recognized to be valid. The analyzer then proceeds to the next
sweep point. Normal detector mode ensures that the measurement is performed at maximum
speed and that a meaningful complex result is obtained.
•
Peak
collects all valid results at each sweep point during the
Meas. Time
set in the
More Ratios
or
More Wave Quantities
dialog and selects the result with the maximum magnitude (maximum
power) as the measurement point. The imaginary part of the measurement point is set to zero.
•
RMS
collects all valid results at each sweep point during the
Meas. Time
set in the
More Ratios
or
More Wave Quantities
dialog and calculates the root mean square (RMS) of the of these
results. This yields the real part of the measurement point. Averaging the phase does not make
sense so the imaginary part of the measurement point is set to zero.
The detector settings have an influence on the displayed trace. They do not affect the number of
measurement points in a sweep (or in a subset of the sweep range) but may increase the
sweep time.
In the
Peak
and
RMS
detector settings, the sweep time can not be smaller than the detector
observation time
(Meas. Time)
set in the
More Ratios
or
More Wave Quantities
dialogs. The sweep time
can be larger if additional delays are taken into account. Changing the
Meas. Time
affects the sweep
time
.
On the other hand, increasing the
Sweep Time
in the
Channel – Sweep
menu leaves the
Meas.
Time
unchanged .
Содержание 1145.1010.04/05/06
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ...Contents of Chapter 1 R S ZVA 1145 1090 62 I 1 2 E 1 Windows XP Embedded 1 22 Firmware Update 1 22...
Страница 48: ......
Страница 70: ......
Страница 72: ......
Страница 90: ......
Страница 92: ......
Страница 108: ......
Страница 156: ......
Страница 162: ......
Страница 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Страница 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Страница 462: ......
Страница 766: ......
Страница 772: ......
Страница 792: ......
Страница 794: ......
Страница 808: ......