![Rohde & Schwarz 1145.1010.04/05/06 Скачать руководство пользователя страница 242](http://html1.mh-extra.com/html/rohde-and-schwarz/1145-1010-04-05-06/1145-1010-04-05-06_operating-manual_1477759242.webp)
Trace Menu
R&S
®
ZVA/ZVB/ZVT
1145.1084.12 4.80
E-6
single trace (*.s1p) or the complete set of S-parameters of an n-port and use the point as
Dec.
Separator;
see
Trace File Formats
.
•
Output Format
selects the format for the exported trace data. In the
Re/Im
format, each
complex measurement value is represented by its real and imaginary part. It is also possible to
store the linear magnitude and phase
(lin Mag-Phase)
or dB magnitude and phase
(dB Mag-
Phase)
of each value.
•
Content
selects only the
Active Trace
or
All Traces of (the) Active Channel
(including all data
and memory traces) for data export to an ASCII (*csv) file.
•
Dec. Separator
selects either the
Point
or the
Comma
(if needed to process the exported data
with an external application) as a separator for decimal numbers exported to an ASCII (*.csv)
file.
•
Ask to Overwrite
activates a message box to be displayed before an older trace file with the
same file name and directory is overwritten.
Selecting an appropriate file format
Use a
Touchstone
file format to export a fixed number of S-parameter data traces to a file that can be
evaluated with applications such as Agilent's Microwave Design System (MDS) and Advanced Design
System (ADS). The data must be acquired in a frequency sweep.
•
*.s1p files are intended for a 1-port S-parameter (the reflection coefficient S11) but can be used
as well to store any single S-parameter. Note that any S-parameter will be labeled S11 in the
file and in the
Select Parameter
box.
•
*.s<n>p files (<n> = 2, 3,, 4) are intended for a complete set of <n>-port S-parameters. Data
export fails if the active channel does not contain the full set of <n>
2
traces.
Use the
ASCII (*.csv)
format if you want to do one of the following:
•
Import the created file into a spreadsheet application such as Microsoft Excel.
•
Export an arbitrary number of traces, multiple traces with the same parameter or memory
traces.
•
Export traces acquired in a power sweep or CW sweep.
•
Use export options.
Use a the
Mathlab (*.dat)
format if you want to import and process the trace data in Mathlab.
For more information see Trace File Formats.
Remote control:
MMEMory:STORe:TRACe "<trc_name>","<file_name>"[,UNFormatted]
Export Formatted Data...
Calls up a dialog to store data or memory traces with their current trace format to a trace file using a
*.csv or *.dat file format. Only the displayed values of the trace (e.g. the logarithmic magnitude, if trace
format
dB Mag
is selected) are exported. Therefore the trace file doesn't necessarily contain the full
(complex) information about the trace.
The exported formatted values correspond to the results in the marker info field. For trace
formats involving Cartesian diagrams (dB Mag, Real, Imag...), the stimulus value and a single
real response value is exported. For circular diagrams, both the real and imaginary part of the
response value is exported.
An exported formatted trace can be processed and evaluated in an external application. Re-import into
the analyzer is only possible if the complex trace values are available.
Содержание 1145.1010.04/05/06
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ...Contents of Chapter 1 R S ZVA 1145 1090 62 I 1 2 E 1 Windows XP Embedded 1 22 Firmware Update 1 22...
Страница 48: ......
Страница 70: ......
Страница 72: ......
Страница 90: ......
Страница 92: ......
Страница 108: ......
Страница 156: ......
Страница 162: ......
Страница 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Страница 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Страница 462: ......
Страница 766: ......
Страница 772: ......
Страница 792: ......
Страница 794: ......
Страница 808: ......