5-10
Note
•
For details of parameters, refer to P.4-16... “Details of parameter”.
Basic gain parameter setup table
Stiffness
1st gain
2nd gain
load variation
suppression
function
Pr1.00
Pr1.01
Pr1.02
Pr1.04
Pr1.05
Pr1.06
Pr1.07
*
2
Pr1.09
Pr6.24
Gain of
position
loop
[0.1 /s]
Gain of
velocity
loop
[0.1 Hz]
Time
constant
of velocity
loop
integration
[0.1 ms]
Time
constant
of torque
filter
[0.01 ms]
Gain of
position
loop
[0.1 /s]
Gain of
velocity
loop
[0.1 Hz]
Time
constant
of velocity
loop
integration
[0.1 ms]
Time
constant
of torque
filter
[0.01 ms]
Load fiuctuation
compensation
filter
[0.01 ms]
0
20
15
3700
1500
25
15
10000
1500
2500
1
25
20
2800
1100
30
20
10000
1100
2500
2
30
25
2200
900
40
25
10000
900
2500
3
40
30
1900
800
45
30
10000
800
2500
4
45
35
1600
600
55
35
10000
600
2500
5
55
45
1200
500
70
45
10000
500
2500
6
75
60
900
400
95
60
10000
400
2500
7
95
75
700
300
120
75
10000
300
2120
8
115
90
600
300
140
90
10000
300
1770
9
140
110
500
200
175
110
10000
200
1450
10
175
140
400
200
220
140
10000
200
1140
11
*
1
320
180
310
126
380
180
10000
126
880
12
390
220
250
103
460
220
10000
103
720
13
*
1
480
270
210
84
570
270
10000
84
590
14
630
350
160
65
730
350
10000
65
450
15
720
400
140
57
840
400
10000
57
400
16
900
500
120
45
1050
500
10000
45
320
17
1080
600
110
38
1260
600
10000
38
270
18
1350
750
90
30
1570
750
10000
30
210
19
1620
900
80
25
1880
900
10000
25
180
20
2060
1150
70
20
2410
1150
10000
20
140
21
2510
1400
60
16
2930
1400
10000
16
110
22
3050
1700
50
13
3560
1700
10000
13
90
23
3770
2100
40
11
4400
2100
10000
11
80
24
4490
2500
40
9
5240
2500
10000
9
60
25
5000
2800
35
8
5900
2800
10000
8
60
26
5600
3100
30
7
6500
3100
10000
7
50
27
6100
3400
30
7
7100
3400
10000
7
50
28
6600
3700
25
6
7700
3700
10000
6
40
29
7200
4000
25
6
8400
4000
10000
6
40
30
8100
4500
20
5
9400
4500
10000
5
40
31
9000
5000
20
5
10500
5000
10000
5
40
*
1 Default stiffness setting: 13 for frames A, B and C, 11 for frames D, E, F.
*
2 In the vertical axis mode or friction compensation mode (Pr0.02 = 3, 4), Pr1.07 keeps 9999 (hold)
until load characteristics estimation completes.
2. Real-Time Auto-Gain Tuning
Basic