7-30
Interface of Communication Connector
• Connection to the host with RS232
• Connection to the host with RS485
4. Communication
Specifications
*
No connection to X5 when no
external scale is used.
Host controller
RS232
interface
SN751701
or equivalent
Motor
Relay
connector
Positioning
controller
TXD
RXD
GND
4
3
1
Servo driver
RXD
TXD
GND
6 RS485+
5
8
7
RS485
−
RS485+
RS485
−
X2
RS485 can be
connecter to either
terminal pair.
X4
X6
Detection
head
External scale unit
Relay
connector
X5
SN751701
or equivalent
Motor
Relay
connector
4
3
1
RXD
TXD
GND
6 RS485+
5 RS485
−
8 RS485+
7 RS485
−
X2
X4
X6
Detection
head
External scale unit
Relay
connector
X5
RS485 can be
connecter to either
terminal pair.
Connect GND terminals of
drivers to common GND to
establish reference voltage
of signals.
*
No connection to X5 when no
external scale is used.
Motor
Relay
connector
X4
X6
Detection
head
External scale unit
Relay
connector
X5
RS485
interface
ADM485
or equivalent
RS485+
RS485–
GND
8
7
Servo driver
X2
RS485+
6
5
1
RS485–
GND
RS485+
RS485–
Host controller
Positioning
controller
Connect GND terminals of
drivers to common GND to
establish reference voltage
of signals.
Communication Method
RS232
RS485
Full duplex, asynchronous
Half duplex, asynchronous
Communication baud rate 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data
8 bit
8 bit
Parity
none
none
Start bit
1 bit
1 bit
Stop bit
1 bit
1 bit
•
Set up the RS232 communication baud rate with Pr5.29, and RS485 communication baud
rate with Pr5.30. The change of these parameters will be validated after the control power
entry. For details, refer to the following list of parameters related to communication.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]