3-32
Note
Related page
represents twisted pair wire.
• P.3-33 “Inputs and outputs on connector X4”
Connection between MINAS A6 and KV-5000/3000 KEYENCE Corp.
Origin sensor input
X axis limit switch CW
X axis limit switch CCW
X axis CW
X sxis deviation
counter clear
X axis CCW
KV-5000/3000
(KEYENCE Corp.)
from
PLC I/O
output
to
PLC I/O
input
GND
+ 24 V
DC24 V
Power supply
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
Driver
PLC
CW limit sensor
Origin proximity
sensor
CCW limit sensor
*
Process of shield wire varies with equipment.
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ-
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY-
ALM+
ALM-
INP+
INP-
COM-
220 Ω
220 Ω
1
3
4
14
15
16
19
26
36
40
2 kΩ
2 kΩ
4.3 kΩ
4.3 kΩ
4.3 kΩ
1.2 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
A6 series
*
Pulse train interface exclusive for line driver
Pulse train interface exclusive for line driver.
Use this interface when you use pulse command frequency
between 500 kpulse/s and 8 Mpulse/s
44
45
46
47
PULSH1
PULSH2
SIGNH1
SIGNH2
Command pulse
input 1
Command sign
input 1
*
When connecting, please make sure to use twisted-pair cable.
*
The internal circuit of the host controller may be changed. About the latest
information please confirm to host controller maker.
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller