To prevent operations by communication (USB/RS232/RS485/Modbus) and operation
from the front panel being in conflict with each other, the following exclusive functions will
be triggered depending on their respective state:
Mode
Locked panel conditions
The front panel is in “execution
display” other than the monitor
mode.
Parameter write and EEPROM write by
communications will result in command error and not
executed. In addition, connection of set-up support
software, PANATERM (USB communication) cannot
be established.
Execution right has been acquired
by RS232/RS485/Modbus
communications.
No operations other than monitor mode can be made
from the front panel.
Set-up support software
(PANATERM)
(USB communication)
is connected.
Please refer to P.7-27 ''Communication'' for RS232/RS485 communications and to Technical
reference (Modbus communication and Block operation Specification) for Modbus
communications.