3-13
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
1. Outline of mode
Full-closed Control Mode
6) Set up appropriate value of hybrid deviation excess (Pr3.28) in command unit, in order to avoid
the damage to the machine.
*
A6-series driver calculates the difference between the encoder position and the external scale
position as hybrid deviation, and is used to prevent the machine runaway or damage in case of
the external scale breakdown or when the motor and the load is disconnected.
If the hybrid deviation excess range is too wide, detection of the breakdown or the disconnection
will be delayed and error detection effect will be lost. If this is too narrow, it may detect the normal
distortion between the motor and the machine under normal operation as an error.
*
When the external scale division ration is not correct, hybrid deviation excess error (Err25.0)
may occur especially when the work travels long distance, even though the external scale and
the motor position matches.
In this case, widen the hybrid deviation excess range by matching the external scale division ra
-
tio to the closest value.
Function
Note
(1) Selection of external scale type
Select the type of external scale to be used.
• Relevant parameters
Parameter
No.
Title
Range
Function
Pr3.23 External scale
selection
0 to 6
Select the type of external scale.
Pr3.26 Reversal of direction of
external scale
0 to 3
Reverse the direction of external scale, feedback
counter.
For details of these parameters, refer to P.4-6 to P.4-85 “Details of parameter”.
Note
(2) Setup of external scale division ratio
Set up the division ratio of encoder resolution and external scale resolution.
• Relevant parameters
Parameter
No.
Title
Range
Function
Pr3.24 Numerator of external
scale division
0 to 2
23
Set up the numerator of the external scale dividing
setup.
Pr3.25
Denominator of
external scale division
1 to 2
23
Set up the Denominator of the external scale
dividing setup.
For details of these parameters, refer to
P.4-6 to P.4-85
“Details of parameter”.
Note
(3) Setup of hybrid excessive deviation
This function detects the positional difference between the motor (encoder) and load
(external scale) and enables the hybrid excessive deviation protection if the difference
exceeds Pr3.28 “Hybrid excessive deviation setup”.
Hybrid excessive deviation is mainly caused by feedback scale error, wrong connection
and loose connection between the motor and load.
• Relevant parameters
Parameter
No.
Title
Range
Function
Pr3.28 Hybrid deviation
excess setup
1 to 2
27
You can setup the permissible gap (hybrid deviation)
between the present motor position and the present
external scale position.
Pr3.29 Hybrid deviation clear
setup
0 to 100
As the motor turns the number of revolutions set by
this parameter, the hybrid deviation is cleared to 0.
For details of these parameters, refer to
P.4-6 to P.4-85
“Details of parameter”.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]