3-34
PI2
Connection to sequence input signals
(Pulse train interface exclusive to line driver)
Related
control mode
P
S
T
F
Line driver I/F (
Permissible max. input frequency of command pulse input signal.: 8 Mpulse/s)
• This signal transmission method has better noise immunity.
We recommend this to secure the signal transmission when line driver I/F is used.
• 1 system: PI2. For function, refer to P.3-38, P.3-39.
AI
Analog command input
Related
control mode
P
S
T
F
• It goes through 3 systems, AI1 to AI3.
• Max. permissible input voltage to each input is ±10 V.
For input impedance of each input, refer to the right Fig.
• When you compose a simple command circuit using variable resistor(VR) and register R,
connect as the right Fig. shows. When the variable range of each input is made as
–10 V to +10 V, use VR with 2 kΩ, B-characteristics, 1/2 W or larger, R with 200 Ω, 1/2 W or
larger.
• A/D converter resolution of each command input is as follows.
(1)ADC1 : 16-bit (AI1)
(2)ADC2 : 12-bit (AI2, AI3)
• For function, refer to P.3-46, P.3-47.
represents twisted pair.
44
45
13
46
47
20 k
Ω
2 k
Ω
2 k
Ω
20 k
Ω
120
Ω
PULS
S GN
20 k
Ω
2 k
Ω
2 k
Ω
20 k
Ω
120
Ω
4. Inputs and outputs on connector X4
Interface Circuit (Input)
Note
Only for the standard type and communication type are not provided with analog input.
+
12 V
SPR
AI3
P-ATL
N-ATL
R
14
15
16
17
18
R
VR
–12 V
AI2
AI1
33.2
kΩ
20
kΩ
20
kΩ
1000 P
1000 P
18.7
kΩ
20
kΩ
+
33.2
kΩ
20
kΩ
20
kΩ
1000 P
1000 P
18.7
kΩ
20
kΩ
+
39
kΩ
39
kΩ
33
kΩ
470 P
470 P
470 P
+
represents twisted pair.