7-9
1
Before Using the Products
2
Preparat
on
3
Connect
on
4
Setup
5
Ad
ustment
6
When
n T
roub
e
7
Supp
ement
1. Safety function
Example of connection
Example of connection when using multiple axes
M
M
M
Sefety output
(source)
EDM
output
EDM output
Servo driver
SF1+
Control
output 1
Control
output 2
0 V
24 V
EDM input
SF1−
SF2+
SF2−
EDM+
EDM
−
Servo driver
SF1+
SF1−
SF2+
SF2−
EDM+
EDM
−
EDM
output
Servo driver
SF1+
SF1−
SF2+
SF2−
EDM+
EDM
−
Safety sensor
•
Capacity requirement per safety output (source) channel: 5 × No. of connected axes (mA)
•
24 VDC supply allowable voltage: 24 V±15 %
•
Maximum No. of connectable axes: 8
*
The number of connectable axes shown in the figure is for reference only.
EDM output depends on external circuit because saturated voltage Vce (sat) of approx.
1.0 V in the built-in photocoupler varies with collector current.
Amount of current flowing to SF input is 5 mA per circuit.
When increasing the number of axes to be connected, make sure that required amount
of current does not exceed the maximum output current of the safety controller.
• P.2-2 “Conformance to international standards” • P.2-74 “How to Use the Front Panel”
• P.3-33 “Inputs and outputs on connector X4”
Re ated page