2-6
1. Conformance to international standards
Composition of Peripheral Equipments
Note
For driver and applicable peripheral equipments, refer to P.2-10 "Driver and List of Applicable
Peripheral Equipments".
Power Supply
100 V type:
(A to C-frame)
Single phase, 100 V
+10 %
–15 %
to 120 V
+10 %
–15 %
50 Hz/60 Hz
200 V type:
(A to D-frame)
Single/3-phase, 200 V
+10 %
–15 %
to 240 V
+10 %
–15 %
50 Hz/60 Hz
200 V type:
(E to F-frame)
3-phase, 200 V
+10 %
–15 %
to 240 V
+10 %
–15 %
50 Hz/60 Hz
(1) This product is designed to be used in over-voltage category (installation category) III
of EN 61800-5-1:2007.
(2) Use an insulated power supply of DC12 to 24 V which has CE marking or complies
with EN60950.
•
Use sheathed (jacketed) cable, twisted cable or closely bundled cable for power cable.
• Power cable and signal wires must be sufficiently isolated from each other.
Twisted
Servo dr ver
L1C
L2C
Closely bundled cable
United
Servo dr ver
L2
L3
L1
Circuit Breaker
Install a circuit breaker which complies with IEC Standards and UL recognized (Listed
and
marked) between power supply and noise filter.
The short-circuit protection circuit on the product is not for protection of branch circuit.
The branch circuit should be protected in accordance with NEC and the applicable local
regulations in your area.
Remarks