6-17
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Time characteristics of Err16.0 (Overload protection)
MQMF Overload protection time characteristics
MSMF Overload protection time characteristics
0.1
1
10
100
1000
100
150
200
250
300
350
Time
[s]
Torque
[%]
MSMF5A, 01, 02 ,04, 08, 09
1
・
MSMF08, 09
When the servo lock
,
Duringthe rotaption
・
MSMF02, 04
When the servo lock
,
Duringthe rotaption
・
MSMF5AZ, 011
When the servo lock
,
Duringthe rotaption
・
MSMF012
When the servo lock
,
Duringthe rotaption
0.1
1
10
100
1000
100
150
200
250
300
350
Time
[s]
Torque
[%]
MSMF10, 15, 20, 30, 40, 50
・
MSMF30 When the servo lock
・
MSMF10, 15, 20, 30, 40, 50
During the rotaption
・
MSMF10, 15, 20, 40, 50 When the servo lock
1
0.1
1
10
100
1000
100
150
200
250
300
350
Time
[s]
Torque
[%]
MQMF01
11
・
MQMF01
When the servo lock
,
Duringthe rotaption
0.1
1
10
100
1000
100
150
200
250
300
350
Time
[s]
Torque
[%]
MQMF02, 04
11
2
・
MQMF02 When the servo lock
・
MQMF04 When the servo lock
・
MQMF02, MQMF04
During the rotaption
Caution
Use the motor so that actual torque stays in the continuous running range shown in “S-T
characteristic” of the motor. For the S-T characteristics, see P.7-55 Motor characteristics
(S-T characteristics).
1. When in Trouble
Protective function (Detail of error code)