5-28
How to Operate
Enter the action command with Pr2.00 Adaptive filter mode set to a value other than 0.
If the resonance point affects the motor speed, parameters of 3rd notch filter and/or 4th
notch filters are automatically set according to the number of adaptive filters.
Set the operation of the adaptive filter to the following parameter.
Class No.
Title
Setup
value
Function
2
00
Adaptive filter
mode setup
0
[Adaptive filter: invalid]
The adaptive filter is disabled. Parameters related to the
3rd and 4th notch filter hold the current value.
1
[Adaptive filter: 1 filter is valid]
One adaptive filter is enabled. Parameters related to
the 3rd notch filter will be updated based on adaptive
performance.
2
[Adaptive filter: 2 filters are valid]
Two adaptive filters are enabled. Parameters related to the
3rd and 4th notch filters will be updated based on adaptive
performance.
3
[Resonance frequency measurement mode]
Measure the resonance frequency. Result of measurement
can be checked with PANATERM. Parameters related to
the 3rd and 4th notch filter hold the current value.
4
[Clear result of adaptation]
Parameters related to the 3rd and 4th notch filter are
disabled and results of adaptive operation are cleared.
5
[High-precision adaptive filter]
Two adaptive filters are enabled. Parameters related to
the 3rd and 4th notch filters will be updated based on the
results of adaptive performance. Use of this setup value is
recommended when using 2 adaptive filters.
6
[For manufacturer's use]
PANATERM’s fit gain function used internally. Do not use
this setup value in the normal condition.
At the same time, the following parameters are automatically set.
Class No.
Title
Function
2
07
3rd notch frequency
In no resonance point is found, the frequency is set to
5000.
2
08
3rd notch width selection
Automatically set when the adaptive filter is active.
2
09
3rd notch depth selection
2
10
4th notch frequency
Notch frequency is automatically set to the 2nd
resonance frequency estimated by the adaptive filter.
In no resonance point is found, the frequency is set to
5000.
2
11
4th notch width selection
Automatically set when 2 adaptive filters are active.
2
12
4th notch depth selection
3. Adaptive filter
Adaptive filter
Related page
• P.4-6 to P.4-85... “Details of parameter”