4-40
Pr4.01
*
SI2 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00818181h
(8487297)
P S T F
Pr4.02
*
SI3 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
0091910Ah
(9539850)
P S T F
Pr4.03
*
SI4 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00060606h
(394758)
P S T F
Pr4.04
*
SI5 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
0000100Ch
(4108)
P S T F
Pr4.05
*
SI6 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00030303h
(197379)
P S T F
Pr4.06
*
SI7 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00000f07h
(3847)
P S T F
Caution
Deviation counter clear (CL) can be set up only with this parameter. If any other parameter
is used for this purpose, Err33.6 Counter clear assignment error will be issued.
Pr4.07
*
SI8 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00040404h
(263172)
P S T F
Pr4.08
*
SI9 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00050505h
(328965)
P S T F
Pr4.09
*
SI10 input selection
Range
Unit
Default
Related
control mode
0 to 00FFFFFFh
—
00000E88h
(3720)
P S T F
Note
Caution
Assign functions to SI2 to SI10 inputs.
These parameters are presented in hexadecimals.
Setup procedure is the same as described for Pr4.00.
For input pin assignment with default setting, also refer to P.3-39 Control input.
Command pulse inhibition input (INH) can be setup only with this parameter. If any other
parameter is used for this purpose, Err33.7 INH assignment error will be issued.
1. Details of parameter
[Class 4] I/F monitor setting
Note
Related page
• A parameter is designated as follows:
Pr0.00 Parameter No.
Class
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.3-32... “Inputs and outputs on connector X4” • P.6-2 “Protective Function”