Pr4.57
Position compare output assignment setting
Range
Unit
Default
Related
control mode
-2147483648 to
2147483647
Command
unit
0
P
F
Sets output terminal corresponding to position compare 1 to 6 by bit.
Multiple position compare can be set to a single output terminal.
・
Set bits
bit
Designation
bit0 ~ 3
Position com 1
bit4 ~ 7
Position com 2
bit8 ~ 11
Position com 3
bit12 ~ 15
Position com 4
bit16 ~ 19
Position com 5
bit20 ~ 23
Position com 6
bit24 ~ 27
Position com 7
bit28 ~ 31
Position com 8
・
Set value
Setup value
Designation
0000
Invalid output
0001
Assigned to SO1 or OCMP1
0010
Assigned to SO2 or OCMP2
0011
Assigned to SO3 or OCMP3
0100
Assigned to SO4 or OCMP4
0101
Assigned to SO5
0110
Assigned to SO6
Others
For manufacturer use (do not set)