3-26
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Note
Related page
represents twisted pair wire.
• P.3-33 “Inputs and outputs on connector X4”
Connection between MINAS A6 and FPG-C32T Panasonic devices SUNX.
A6 series
FPG-C32T
(Panasonic devices SUNX.)
from
PLC I/O
output
to
PLC I/O
input
GND
+ 24 V
DC24 V
Power supply
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
Driver
PLC
CCW limit sensor
Origin proximity sensor
CW limit sensor
CW pulse command
output
CCW pulse command
output
Origin input
Deviation counter
reset output
Origin proximity input
CCW limit excess
input
CW limit excess
input
*
Process of shield wire varies with equipment.
Y0
Y1
X2
COM
+
Y2
-
COM
X3
X5
X6
5.6 kΩ
3 kΩ
5.6 kΩ
5.6 kΩ
○
○
50
3
4
5
6
19
13
25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
CZ
GND
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY-
ALM+
ALM-
INP+
INP-
COM-
220 Ω
220 Ω
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
*
When connecting, please make sure to use twisted-pair cable.
*
The internal circuit of the host controller may be changed. About the latest
information please confirm to host controller maker.
2 kΩ
2 kΩ
2 kΩ
2 kΩ