5-76
7. Applied functions
Position compare output function
・
When using generic outputs (SO1 to SO6) as position compare output (CMP-OUT), assign
position compare output to Pr4.40 to 4.15 under all control mode.
・
Position compare output function automatically compensates the output for errors caused
by time delay of encoder serial communications, etc., taking reference on the previous
motor velocity. Furthermore, the amount of compensation can be set by adjustment of
Pr4.56 “Position compare output delay compensation amount”.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]