4-74
Note
Related page
• A parameter is designated as follows:
Pr0.00 Parameter No.
Class
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.3-32... “Inputs and outputs on connector X4”
Default: [ ]
Pr6.32
Real time auto tuning custom setup
Range
Unit
Default
Related
control mode
−32768 to 32767
—
0
P S T F
When the operation mode of real time auto tuning is set to the customize (Pr0.02 = 6), set
the automatic adjusting function as shown below.
When the two-degree-of-freedom control mode is set , use with Pr6.32 = 0.
Bit
Content
Description
1 to 0
Load char-
acteristics
estimation
*
Enable/disable the load characteristics estimation function.
Setup value
Function
[0]
Disable
1
Enable
*
If the load characteristics estimation is disabled, the current setup
cannot be changed even if the inertia ratio is updated according to
the estimated value. When the torque compensation is updated by
the estimated value, it is cleared to 0 (invalid).
*
To enable the load characteristics measurement, set Pr6.31 Real
time auto tuning estimation speed to a value other than 0 (stop
estimation).
3 to 2
Inertia ratio
update
Set up update to be made based on result of the load characteristics
estimation of Pr0.04 Inertia ratio.
Setup value
Function
[0]
Use the current setup.
1
Update by the estimated value.
*
To enable the inertia ratio update, set Bits 1-0 (load characteristic
measurement) to 1 (enable). The inertia ratio will not be updated
unless both settings are made valid.
6 to 4
Torque
compensation
Set up the update to be made according to the results of load
characteristics estimation of Pr6.07 Torque command additional
value, Pr6.08 positive direction torque compensation value and Pr6.09
negative direction torque compensation value.
Setup value
Function
Compensation setup
[0]
Use current setup
Pr6.07 Pr6.08 Pr6.09
1
Disable torque compensation 0 clear 0 clear 0 clear
2
Vertical axis mode
Update 0 clear 0 clear
3
Friction compensation
(low)
Update
Low
Low
4
Friction compensation
(middle)
Update Middle Middle
5
Friction compensation
(high)
Update
High
High
*
To enable the torque compensation (set to 2-5), set Bits 3-2 (Inertia
ratio update) to 1 (enable). It is not possible to update only the
torque compensation.
(continued)
1. Details of parameter
[Class 6] Special setting