2-100
(2) Analog inputs 1 to 3 automatic offset adjustment
This function automatically adjusts offset setting of analog input.
Analog input 1 (AI1)......Pr4.22 (Analog input 1 (AI1) offset setup)
Analog input 2 (AI2)......Pr4.25 (Analog input 2 (AI2) offset setup)
Analog input 3 (AI3)......Pr4.28 (Analog input 3 (AI3) offset setup)
Remarks
Note
•
You cannot write the data only by executing automatic offset adjustment.
Execute a writing to EEPROM when you need to reflect the result afterward.
•
After completion of the automatic offset adjustment, return to SELECTION display by
referring to P.2-76 “Structure of Each Mode”.
• When you execute automatic offset adjustment, make
command input to 0 V,then keep pressing until the display
changes to .
• Press to call for
EXECUTION display.
(SET button)
Automatic offset
adjustment finishes.
Automatic offset adjustment starts.
*
Example of Analog input1(AI1).
Error occurs.
Adjustment
finishes.
(
Invalid mode is selected,
)
or offset value exceeds
the setup range of Pr4.22.
“ ” increases while keep
pressing (for approx. 5sec)
as the left fig. shows.
(SET button)
SELECTION display
EXECUTION display
14. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)