7-111
1
Before Using the Products
2
Preparat
on
3
Connect
on
4
Setup
5
Ad
ustment
6
When
n T
roub
e
7
Supp
ement
7
7. Options
Supplement
Ferrite core
Install ferrite core for signal lines to all cables (power cable, motor cable, encoder cable
and interface cable)
• Options
<24 V Power cable, Motor cable, Encoder cable, Interface cable, USB cable>
Option part No.
Manufacturer's part No.
Manufacturer
DV0P1460
ZCAT3035-1330
TDK Corp.
[Unit: mm]
39±1
34±1
30±1
13
±1
Mass: 62.8
g
To connect the noise filter to
the connector XB connection
cable, adjust the sheath length
at the tip of the cable, as
required.
Remarks
• Recommended components
Part No.
Applicable driver (frame)
Manufacturer
RJ8035
E-frame 200 V, F-frame 200 V
KK-CORP.CO.JP
B
A
C
D1
F
E
D2
Manufacturer's
part No.
Current
value
100kHz
(μH)
Dimension [Unit: mm]
A
B
C
D1
D2
Core thikness
E
F
RJ8035
35 A
9.9±3
170
150
23
80
53
24
R3.5
7
Remarks
Fix the signal line ferrite core in place to eliminate excessive stress to the cables.
<Power cable>