3-56
Control Output Settings
5. IF Monitor Settings
How to Assign Various I/O Functions to the I/F
Title of signal
Connector X4
Pin No.
Parameter No.
SO1 output
10, 11
Pr4.10
SO2 output
34, 35
Pr4.11
SO3 output
36, 37
Pr4.12
SO4 output
38, 39
Pr4.13
SO5 output
12
Pr4.14
SO6 output
40
Pr4.15
(e.g. 1) Parameter setting
00 03 03 03 h (Hexadecimal numbers)
Position/ Full-closed Control (External brake release signal)
Velocity Control
(External brake release signal)
Torque Control
(External brake release signal)
Convert to a decimal number
197379
Enter this value to the relevant parameter.
(e.g. 2) Parameter setting
00 05 05 04 h (Hexadecimal numbers)
Position/ Full-closed Control (Positioning complete)
Velocity Control
(Speed arrival output)
Torque Control
(Speed zero clamp input; b-contact)
Convert to a decimal number
328964
Enter this value to the relevant parameter.
Caution
Note
•
Same function can be assigned to 2 or more output signals.
•
Control output pin set to invalid always has the output transistor turned OFF.
•
Do not change the setup value shown in the table.
*
1 Note that the setup values are displayed in decimal on the front panel.
• Output circuit, refer to P.3-35, 36 and function, refer to P.3-48 to P.3-51.
Related page
P.4-41
These parameters shall be set by using
hexadecimal numbers. Setting shall be made for
each control mode as shown in examples below.
00
ーーーー▲▲
h: Position/Full-closed control
00
ーー**ーー
h: Speed control
00
■■ーーーー
h: Torque control
Set an appropriate function number in place of
“
■■
”, “
**
” and “
▲▲
”. For the function
number, see the table on the right.
Setup
value
Title
Symbol
00h
Invalid
−
01h
Servo alarm output
ALM
02h
Servo-Ready output
S-RDY
03h
External brake release
signal
BRK-OFF
04h
Positioning complete output
INP
05h
At-speed output
AT-SPEED
06h
Torque in-limit signal output
TLC
07h
Zero-speed detection output signal
ZSP
08h
Speed coincidence output
V-COIN
09h
Alarm output 1
WARN1
0Ah Alarm output 2
WARN2
0Bh
Positional command ON/OFF output
P-CMD
0Ch Positioning complete 2
INP2
0Dh
Speed in-limit output
V-LIMIT
0Eh Alarm attribute output
ALM-ATB
0Fh Speed command ON/OFF output
V-CMD
10h
Servo on status output
SRV-ST
14h
Position compare output
CMD-OUT
15h
Deterioration diagnosis velocity output
V-DIAG
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]