5-18
Basic gain parameter setup table
Stiffness
1st gain/2nd gain
Command response
Adjustment
filter
load variation
suppression
function
Pr1.00
Pr1.05
Pr1.01
Pr1.06
Pr1.02
Pr1.07
Pr1.04
Pr1.09
Pr2.22
Pr6.48
*
1
Pr6.24
Position
loop
[0.1 /s]
Velocity
loop
[0.1 Hz]
Velocity
loop
integration
[0.1 ms]
Torque
[0.01 ms]
Time
constant [0.1 ms]
Time
constant
[0.1 ms]
Load fiuctuation
compensation
filter
[0.01 ms]
Standard
response
mode
Quick
response
mode
1 to 3
0
20
15
3700
1500
1919
764
155
2500
1
25
20
2800
1100
1487
595
115
2500
2
30
25
2200
900
1214
486
94
2500
3
40
30
1900
800
960
384
84
2500
4
45
35
1600
600
838
335
64
2500
5
55
45
1200
500
668
267
54
2500
6
75
60
900
400
496
198
44
2500
7
95
75
700
300
394
158
34
2120
8
115
90
600
300
327
131
34
1770
9
140
110
500
200
268
107
24
1450
10
175
140
400
200
212
85
23
1140
11
320
180
310
126
139
55
16
880
12
390
220
250
103
113
45
13
720
13
480
270
210
84
92
37
11
590
14
630
350
160
65
71
28
9
450
15
720
400
140
57
62
25
8
400
16
900
500
120
45
50
20
7
320
17
1080
600
110
38
41
17
6
270
18
1350
750
90
30
33
13
5
210
19
1620
900
80
25
28
11
5
180
20
2060
1150
70
20
22
9
4
140
21
2510
1400
60
16
18
7
4
110
22
3050
1700
50
13
15
6
3
90
23
3770
2100
40
11
12
5
3
80
24
4490
2500
40
9
10
4
3
60
25
5000
2800
35
8
9
4
2
60
26
5600
3100
30
7
8
3
2
50
27
6100
3400
30
7
7
3
2
50
28
6600
3700
25
6
7
3
2
40
29
7200
4000
25
6
6
2
2
40
30
8100
4500
20
5
6
2
2
40
31
9000
5000
20
5
5
2
2
40
*
1 The value of Pr6.48 Adjustment filter has additional value 1 for B to F frames.