2-5
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Caution
Use options correctly after reading Operating Instructions of the options to better understand
the precautions.
Take care not to apply excessive stress to each optional part.
1. Conformance to international standards
Composition of Peripheral Equipment
Ferrite coil
Symbol
*
1
Cable Name
Amp. frame symbol
Option
part No.
Manufacturer's
part No.
Manufacturer
Qty.
NF1
Power cable
(100 V)C
(200 V)C, D
DV0P1460 ZCAT3035-1330
TDK Corp.
0
(100 V)A, B
(200 V)A, B, E
1
NF2
Motor cable
(100 V)A, B, C
(200 V)A, B, C, D, E
1
(200 V)F
2
*1 For symbols, refer to the Block Diagram “Installation Environment” (P.2-4).
*2 The number of turns are 0.
Remarks
Caution
To connect the noise filter to the connector XB connection cable, adjust the sheath length
at the tip of the cable, as required.
Fix the ferrite coil in order to prevent excessive stress to the cables.
<Attaching ferrite coil>
Signal wire
Wind cables the number of turns required to form the ferrite coil.
Power wire
If sheathed (jacketed): remove the sheath (jacket) to the length so that wires (L1,
L2, L3) can be wound on the ferrite coil (including power line dedicated filter). For
effective noise reduction capability, L1, L2 and L3 should be wound together.
If not effective, increase the number of signal noise filters (including power line
dedicated filters). (See figure below.)
Motor line
When installing the ferrite coil (including motor line dedicated filter) to our optional
cable, remove the sheath (jacket) to the length so that wires can be wound on
the ferrite coil (including power line dedicated filter). For effective noise reduction
capability, U, V and W should be wound together.
If not effective, increase the number of ferrite coils (including power line dedicated
filters). (See figure below.)
Encoder line
Wind cables the number of turns required to form the ferrite coil.
Sheath (jacket)
Cover
FG line
Electric wire
Sheath (jacket)
*
If not effective, increase
the number of turns.
*
If not effective, increase
the number of turns.
Cover
DV0P1460
FG line
Electric wire
Sheath (jacket)
*
If not effective, increase
the number of filters.
Cover
DV0P1460
FG line
Electric wire