4. Inputs and outputs on connector X4
Input Signal and Pin No.
Function allocatable to control input
Title of
signal
Servo-ON input
Related
control mode
P
S
T
F
Symbol
SRV-ON
Default assignment
29 (SI6)
I/F circuit
SI P.3-33
• This signal turns on/off the servo (motor).
Title of
signal
Positive direction over-travel inhibition input
Related
control mode
P
S
T
F
Symbol
POT
Default assignment
9 (SI2)
I/F circuit
SI P.3-33
• Positive direction over-travel inhibit input.
• The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
• When using this input, set Pr5.04 “Setup of over-travel inhibit input” to a value other than 1
so that the input is OFF when the moving portion of the machine exceeds this signal range
toward positive direction.
Title of
signal
Negative direction over-travel inhibition input
Related
control mode
P
S
T
F
Symbol
NOT
Default assignment
8 (SI1)
I/F circuit
SI P.3-33
• Negative direction over-travel inhibit input.
• The operation with this input turned ON is set up in Pr5.04 “Setup of over-travel inhibit
input”.
• When using this function, set Pr5.04 “Setup of over-travel inhibit input” to a value other
than 1 so that the input is OFF when the moving portion of the machine exceeds this signal
range toward negative direction.
Title of
signal
Deviation counter clear input
Related
control mode
P
S
T
F
Symbol
CL
Default assignment
30 (SI7)
I/F circuit
SI P.3-33
Caution
• Clears the positional deviation counter.
• Default setup clears the counter at the rising edge of the clear input, To change the setup,
modify it in the Pr5.17 “Counter clear input mode”.
<Signal width and clear timing>
Pr5.17
CL signal width
Deviation clear timing
1
500 μs or more
Continually clear the counter while the deviation counter
clear input is ON.
*
1
2
1 ms or more
3
100 μs or more
Only once clear the counter at OFF to ON edge of the
deviation counter clear input signal.
*
1
4
1 ms or more
*
1 Deviation counter clear input ON/OFF = input photocoupler ON/OFF
This function can be assigned to only SI7. Allocation of this function to any other pin will
cause an error.
Related page
• P.4-52, 57 “Details of Parameter”