4-23
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Pr2.00
Adaptive filter mode setup
Range
Unit
Default
Related
control mode
0 to 6
—
Basic type:1
Communication type:1
Multifunction typ:0
P S
F
Set up the resonance frequency to be estimated by the adaptive filter and specify the
operation after estimation.
Setup value
Content
[0]
Adaptive filter:
invalid
Parameters related to the 3rd and 4th notch filter hold the
current value.
1
Adaptive filter:
1 filter is valid
One adaptive filter is enabled. Parameters related to the 3rd
notch filter will be updated based on adaptive performance.
2
Adaptive filter:
2 filters are valid
Two adaptive filters are enabled. Parameters related to the
3rd and 4th notch filters will be updated based on adaptive
performance.
3
Resonance frequency
measurement mode
Measure the resonance frequency. Result of measurement
can be checked with PANATERM. Parameters related to the
3rd and 4th notch filter hold the current value.
4
Clear result of
adaptation
Parameters related to the 3rd and 4th notch filter are
disabled and results of adaptive operation are cleared.
5
High-precision
adaptive filter
Two adaptive filters are enabled. Parameters related to
the 3rd and 4th notch filters will be updated based on the
results of adaptive performance. Use of this setup value is
recommended when using 2 adaptive filters.
6
For manufacturer's
use
PANATERM’s fit gain function used internally.
Do not use this setup value in the normal condition.
Pr2.01
1st notch frequency
Range
Unit
Default
Related
control mode
50 to 5000
Hz
5000
P S T F
Caution
Set the center frequency of the 1st notch filter.
The notch filter function will be invalidated by setting up this parameter to "5000".
Pr2.02
1st notch width selection
Range
Unit
Default
Related
control mode
0 to 20
—
2
P S T F
Caution
Set the width of notch at the center frequency of the 1st notch filter.
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.03
1st notch depth selection
Range
Unit
Default
Related
control mode
0 to 99
—
0
P S T F
Caution
Set the depth of notch at the center frequency of the 1st notch filter.
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.04
2nd notch frequency
Range
Unit
Default
Related
control mode
50 to 5000
Hz
5000
P S T F
Caution
Set the center frequency of the 2nd notch filter.
The notch filter function will be invalidated by setting up this parameter to "5000".
4
1. Details of parameter
Setup
[Class 2] Damping control
Default: [ ]