2-58
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
P S T F
3
22
Speed limit value 2
0 to 20000
0
r/min
○
4-36
3
23
External scale selection
0 to 6
0
−
○
○
4-37
3
24
Numerator of external scale division
0 to 2
23
0
−
○
○
3
25
Denominator of external scale division
1 to 2
23
10000
−
○
○
3
26
Reversal of direction of external scale
0 to 3
0
−
○
○
4-38
3
27
External scale Z phase disconnection
detection disable
0 to 1
0
−
○
○
3
28
Hybrid deviation excess setup
1 to 2
27
16000
Command
unit
○
○
3
29
Hybrid deviation clear setup
0 to 100
0
Revolution
○
○
[Class 4] I/F monitor setting
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
P S T F
4
00
SI1 input selection (Pin No.8)
0 to 00FFFFFFh
8553090
−
○
○ ○ ○ ○
4-39
4
01
SI2 input selection (Pin No.9)
0 to 00FFFFFFh
8487297
−
○
○ ○ ○ ○
4-40
4
02
SI3 input selection (Pin No.26)
0 to 00FFFFFFh
9539850
−
○
○ ○ ○ ○
4
03
SI4 input selection (Pin No.27)
0 to 00FFFFFFh
394758
−
○
○ ○ ○ ○
4
04
SI5 input selection (Pin No.28)
0 to 00FFFFFFh
4108
−
○
○ ○ ○ ○
4
05
SI6 input selection (Pin No.29)
0 to 00FFFFFFh
197379
−
○
○ ○ ○ ○
4
06
SI7 input selection (Pin No.30)
0 to 00FFFFFFh
3847
−
○
○ ○ ○ ○
4
07
SI8 input selection (Pin No.31)
0 to 00FFFFFFh
263172
−
○
○ ○ ○ ○
4
08
SI9 input selection (Pin No.32)
0 to 00FFFFFFh
328965
−
○
○ ○ ○ ○
4
09
SI10 input selection (Pin No.33)
0 to 00FFFFFFh
3720
−
○
○ ○ ○ ○
4
10
SO1 output selection (Pin No.10, 11)
0 to 00FFFFFFh
197379
−
○
○ ○ ○ ○
4-41
4
11
SO2 output selection (Pin No.34, 35)
0 to 00FFFFFFh
131586
−
○
○ ○ ○ ○
4
12
SO3 output selection (Pin No.36, 37)
0 to 00FFFFFFh
65793
−
○
○ ○ ○ ○
4
13
SO4 output selection (Pin No.38, 39)
0 to 00FFFFFFh
328964
−
○
○ ○ ○ ○
4
14
SO5 output selection (Pin No.12)
0 to 00FFFFFFh
460551
−
○
○ ○ ○ ○
4
15
SO6 output selection (Pin No.40)
0 to 00FFFFFFh
394758
−
○
○ ○ ○ ○
12. Setup of Parameter and Mode
List of Parameters
Note
Parameter describes of this page is P.4-6 to P.4-85.
• Partial parameter of standard type and communication type are different from a table in a shipment parameter.
• Definition of symbols under “Power Off/On” - : if a change is made, it will be reflected upon the parameter when the
power to the driver is turned off and then on again.
• Definition of symbols under “Related mode” - P: position control, S: velocity control, T: torque control, F: full closed control