4. Communication
Details of Communication Command
command
9
mode
4
• Alarm clear
Recept on data
0
axis
checksum
9
4
Error code
Transm ss on data
• Clears currently activated alarm (only in case of alarms that can be cleared).
• Also clears absolute battery alarm.
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
1
axis
Error code
checksum
9
4
command
9
mode
3
• Clear alarm history
Recept on data
0
axis
checksum
9
3
Error code
Transm ss on data
• Clears alarm data history.
• Data error in case of clear failure.
• In case of control power supply LV, error code Control LV will be returned and write will not take place.
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
1
axis
Error code
checksum
9
3
Data Error
Command error RS485 error
Command error RS485 error
Control LV
command
9
mode
2
• Read batch alarm history
Recept on data
Error code
Transm ss on data
• Reads alarm going back 14 times in the past.
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
Command error Command error
Previous
Two times before
14 times before
0
axis
checksum
9
2
29 (1Dh)
axis
Alarm No. (Main)
Alarm No. (Sub)
Alarm No. (Main)
Alarm No. (Sub)
Alarm No. (Main)
Alarm No. (Sub)
Error code
checksum
9