2-29
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
2.
System Configuration and Wiring
Specifications of Motor connector
Do not connect anything to NC.
Remarks
PIN No. Application
U-phase
V-phase
W-phase
NC
NC
Ground
1
2
3
4
5
PE
1
2
3
4
5
PIN No. Application
U-phase
V-phase
W-phase
Brake
Brake
Ground
PE
PIN No. Application
U-phase
V-phase
W-phase
NC
NC
Ground
1
2
3
4
5
PE
1
2
3
4
5
PIN No. Application
U-phase
V-phase
W-phase
Brake
Brake
Ground
PE
PE
3
4
5
2
1
3
4
5
2
1
PE
Connector for motor
Connector for motor
[Motor with brake]
Connector for motor and brake
[Motor with brake]
Connector for motor and brake
MQMF, MHMF(200 W to 1.0 kW(
□
80))
MHMF(50 W, 100 W)
Tightening torque of the screw (M2) 0.085 N·m to 0.095 N·m
(screwed to plastic)
*
Be sure to use only the screw supplied with the connector, to avoid
damage.
Tightening torque of the screw (M2) 0.085 N·m to 0.095 N·m
(screwed to plastic)
*
Be sure to use only the screw supplied with the connector, to avoid
damage.
JN11AH06NN2
JN11AH06NN1
*
Electromagnetic brake is a nonpolar device.
*
Electromagnetic brake is a nonpolar device.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]