2-59
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
P S T F
4
16
Type of analog monitor 1
0 to 28
0
−
○ ○ ○ ○
4-42
4
17
Analog monitor 1 output gain
0 to 214748364
0
−
○ ○ ○ ○
4
18
Type of analog monitor 2
0 to 28
4
−
○ ○ ○ ○
4
19
Analog monitor 2 output gain
0 to 214748364
0
−
○ ○ ○ ○
4
20
For manufactuer's use
−
0
−
4
21
Analog monitor output setup
0 to 2
0
−
○ ○ ○ ○
4-44
4
22
Analog input 1 (AI1) offset setup
−5578 to 5578
0
0.366 mV
○ ○ ○ ○
4
23
Analog input 1 (AI1) filter
0 to 6400
0
0.01 ms
*
○ ○ ○ ○
4
24
Analog input 1 (AI1) overvoltage setup
0 to 100
0
0.1 V
*
○ ○ ○ ○
4
25
Analog input 2 (AI2) offset setup
−342 to 342
0
5.86 mV
○ ○ ○ ○
4
26
Analog input 2 (AI2) filter
0 to 6400
0
0.01 ms
*
○ ○ ○ ○
4
27
Analog input 2 (AI2) overvoltage setup
0 to 100
0
0.1 V
*
○ ○ ○ ○
4
28
Analog input 3 (AI3) offset setup
−342 to 342
0
5.86 mV
○ ○ ○ ○
4
29
Analog input 3 (AI3) filter
0 to 6400
0
0.01 ms
*
○ ○ ○ ○
4-45
4
30
Analog input 3 (AI3) overvoltage setup
0 to 100
0
0.1 V
*
○ ○ ○ ○
4
31
Positioning complete (In-position) range
0 to 2097152
10
Command
unit
○
○
4
32
Positioning complete (In-position) output
setup
0 to 10
0
−
○
○
4
33
INP hold time
0 to 30000
0
1 ms
○
○
4-46
4
34
Zero-speed
10 to 20000
50
r/min
○ ○ ○ ○
4
35
Speed coincidence range
10 to 20000
50
r/min
○ ○
4
36
At-speed (Speed arrival)
10 to 20000
1000
r/min
○ ○
4-47
4
37
Mechanical brake action at stalling setup
0 to 10000
0
1 ms
○ ○ ○ ○
4
38
Mechanical brake action at running setup
0 to 10000
0
1 ms
○ ○ ○ ○
4
39
Brake release speed setup
30 to 3000
30
r/min
○
○ ○ ○ ○
4-48
4
40
Selection of alarm output 1
0 to 28
0
−
○ ○ ○ ○
4
41
Selection of alarm output 2
0 to 28
0
−
○ ○ ○ ○
4
42
2nd Positioning complete (In-position)
range
0 to 2097152
10
Command
unit
○
○
4
44
Position compare output pulse width
setting
0 to 32767
0
0.1ms
○
○
○
4-49
12. Setup of Parameter and Mode
List of Parameters
Caution
Note
The symbol “
*
” attached to “Unit”. indicates that the digits of setting unit will change if the
parameter is set by using the setup support software PANATERM.
Parameter describes of this page is P.4-6 to P.4-85.
• Partial parameter of standard type and communication type are different from a table in a shipment parameter..
• Definition of symbols under “Power Off/On” - : if a change is made, it will be reflected upon the parameter when the
power to the driver is turned off and then on again.
• Definition of symbols under “Related mode” - P: position control, S: velocity control, T: torque control, F: full closed control
*
1 Default settings depend on the combination of driver and motor. Refer to P. 2-84 “Torque limit setting”.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]