(5) Initialization of parameter
Initialize the parameter.
Initialization of
parameter completes
Error occurs
(Minor error occurs)
Initialization of parameter
Initialization
finishes
• Press to call for
EXECUTION display.
(SET button)
SELECTION display
EXECUTION display
“ ” increases while keep
pressing (for approx. 5sec)
as the left fig. shows.
• Keep pressing until the display changes to
when you execute Initialization of parameter.
Caution
•
Parameter cannot be initialized when one of the following error occurs: Err11.0 “Under
voltage protection of control power supply”, EEPROM related errors (Err36.0, Err36.1,
Err36.2, Err37.0, Err37.1 and Err37.2) - initialization will result in “Error” display.
14. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)
Note
•
After initialization of parameter finishes, return to SELECTION display, referring to structure
of each mode (P.2-76).