3-28
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Note
Related page
represents twisted pair wire.
• P.3-33 “Inputs and outputs on connector X4”
Connection between MINAS A6 and F3NC32-ON/F3NC34-ON Yokogawa Electric Corp.
A6 series
F3NC32-ON/F3NC34-ON
(Yokogawa Electric Corp.)
GND
+ 24 V
DC24 V
Power supply
Driver
PLC
CCW limit sensor
Origin proximity sensor
CW limit sensor
Pulse output A
Pulse output B
Origin input
Deviation counter
reset output
Contact point
input COM
External power supply
24 VDC input
External power supply
24 VDC input (GND)
Negative direction
limit input
Positive direction
limit input
Encoder Z-phase
input +
Encoder Z-phase
input –
*
Process of shield wire varies with equipment.
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ-
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY-
ALM+
ALM-
INP+
INP-
COM-
220 Ω
220 Ω
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4a
3a
6a
5a
19a
20a
17a
14a
1a
1b
13a
9a
8a
7a
240
Ω
7.4 kΩ
7.4 kΩ
7.4 kΩ
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
from
PLC I/O
output
to
PLC I/O
input
*
When connecting, please make sure to use
twisted-pair cable.
*
Pulse train interface exclusive for line driver
44
45
46
47
PULSH1
PULSH2
SIGNH1
SIGNH2
Command pulse
input 1
Command sign
input 1
Pulse train interface exclusive for line driver.
Use this interface when you use pulse command frequency
between 500 kpulse/s and 8 Mpulse/s
.
In this case, please make sure to connect the signal ground
of the amplifier and controller.
*
The internal circuit of the controller may be changed.
About the latest information please confirm to the
controller maker.