3-30
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Note
Related page
represents twisted pair wire.
• P.3-33 “Inputs and outputs on connector X4”
Connection between MINAS A6 and CJ1W-NC133 Omron Corp.
Driver
PLC
A6 series
CJ1W-NC133
(Omron Corp.)
from
PLC I/O
output
to
PLC I/O
input
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
GND
+ 24 V
DC24 V
Power supply
GND
+ 5 V
DC5 V
Power supply
CCW limit sensor
Origin proximity sensor
CW limit sensor
CW pulse command
output
CCW pulse command
output
Origin line driver
input
Deviation counter
reset output
24 V power supply
for output
Emergency stop
input
Origin proximity input
CCW limit over input
CW limit over input
5 V power supply
for pulse output
50
3
4
5
6
23
24
13,25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ-
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY-
ALM+
ALM-
INP+
INP-
COM-
220 Ω
220 Ω
*
Process of shield wire varies with equipment.
A5
A6
A7
A8
A14
A12
A1
A2
A10
A20
A16
A17
A19
A18
A3
A4
+V
GND
150
Ω
GND
+V
4.7 kΩ
1.6 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
4.7 kΩ
*
When connecting, please make sure to use twisted-pair cable.
*
The internal circuit of the host controller may be changed. About the latest
information please confirm to host controller maker.