7-24
2. Absolute system
Transferring external scale absolute data
(1) Alarm No. A8 “External scale error alarm”
(5) Err51.3 “External scale status 3 error protection”
(6) Err51.2 “External scale status 2 error protection”
(7) Err51.1 “External scale status 1 error protection”
(8) Err51.0 “External scale status 0 error protection”
(2) Alarm No. A8 “External scale error alarm”
(3) Err51.5 “External scale status 5 error protection”
(4) Err51.4 “External scale status 4 error protection”
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Logical sum of bit6 and bit 7 of external scale status (L)
Logical sum of bit0 to bit 5 of external scale status (L)
• External scale status (L)-----1 represents error occurrence.
• External scale status (H)-----1 represents error occurrence.
External scale status (L)
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
0
External scale status (H)
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
0
0
0
0
0
0
Remarks
For detail of the external scale status, refer to the external scale specification.
Remarks
• Transmit the External scale absolute data while fixing the motor with
brake by turning to Servo-Off.
• P.6-3 “Protective Function” • P.7-25 “Display of Battery Alarm”
Re ated page