4-47
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Note
Related page
• A parameter is designated as follows:
Pr0.00 Parameter No.
Class
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated
when you turn on the control power.
• P.3-32... “Inputs and outputs on connector X4”
Pr4.36
At-speed (Speed arrival)
Range
Unit
Default
Related
control mode
10 to 20000
r/min
1000
S T
Set the detection timing of the speed arrival output (AT-SPEED).
When the motor speed exceeds this setup value, the speed arrival output (AT-SPEED) is
output. Detection is associated with 10 r/min hysteresis.
ON
ON
OFF
OFF
Time
Motor speed
Speed
[r/min]
Pr4.36+10
Pr4.36−10
−(Pr4.36−10)
−(Pr4.36+10)
the speed
arrival output
AT-SPEED
Pr4.37
Mechanical brake action at stalling setup
Range
Unit
Default
Related
control mode
0 to 10000
1 ms
0
P S T F
You can set up the time from when the brake release signal (BRK-OFF) turns off to when the
motor is de-energized (Servo-free), when the motor turns to Servo-OFF while the motor is at stall.
• Set up to prevent a micro-travel/ drop of
the motor (work) due to the action delay
time (tb) of the brake
• After setting up Pr4.37 ≥ tb ,
then compose the sequence so as the
driver turns to Servo-OFF after the brake
is actually activated.
ON
SRV-ON
BRK-OFF
actual brake
motor
energization
release
OFF
hold
release
energized
hold
non-
energized
Pr4.37
tb
Pr4.38
Mechanical brake action at running setup
Range
Unit
Default
Related
control mode
0 to 32000
1 ms
0
P S T F
You can set up time from when detecting the off of Servo-ON input signal (SRV-ON) is to
when external brake release signal (BRK-OFF) turns off, while the motor turns to servo off
during the motor in motion.
• Set up to prevent the brake deterioration
due to the motor running.
• At Servo-OFF during the motor is
running, tb of the right fig. will be a
shorter one of either Pr4.38 setup time,
or time lapse till the motor speed falls
below Pr4.39 setup speed.
tb
ON
SRV-ON
BRK-OFF
motor
energization
release
OFF
hold
actual
brake
energized
non-
energized
Pr4.39
setup speed.
1. Details of parameter
[Class 4] I/F monitor setting