4-49
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Default: [ ]
Pr4.44
Position compare output pulse width setting
Range
Unit
Default
Related
control mode
0
~
32767
0.1 ms
0
P S T F
Sets the signal width of position compare output.
No signal will be output when 0.
Pr4.45
Position compare output polarity select
Range
Unit
Default
Related
control mode
0
~
63
—
0
P
F
Sets polarity of position compare output by bit for each output terminal.
・
Set bits
bit
Designation
bit0
SO1 or OCMP1
bit1
SO2 or OCMP2
bit2
SO3 or OCMP3
bit3
SO4 or OCMP4
bit4
SO5
bit5
SO6
・
Set value
Setup value
Designation
0
Output photocoupler for SO 1 to 6 will turn ON during pulse output and OCMP 1 to 4
will be L level respectively.
1
Output photocoupler for SO1 to 6 will turn OFF during pulse output and OCMP 1 to 4
will be H level respectively,
Use 0 normally.
Pr4.47
Pulse output select
Range
Unit
Default
Related
control mode
0
~
7
—
0
P S T F
Selects signal to be output from pulse regeneration output / position compare output
terminal.
Setup value
Designation
[0]
OA/OB/OZ/CZ
1
OCMP1/OCMP2/OZ/CZ
2
OA/OB/OCMP3/OCMP3
3
OCMP1/OCMP2/OCMP3/OCMP3
4
OA/OB/OZ/OCMP4
5
OCMP1/OCMP2/OZ/OCMP4
6
OA/OB/OCMP3/OCMP4
7
OCMP1/OCMP2/OCMP3/OCMP4
*The signal of OA, OB, OZ, CZ is pulse regeneration output,the signal of OCMP1, OCMP2,
OCMP3, OCMP4 is position compare output terminal.
Pr4.48
Position compare value 1
Range
Unit
Default
Related
control mode
-2147483648 to
2147483647
Command
unit
0
P
F
Sets comparison value for position compare 1.
1. Details of parameter
[Class 4] I/F monitor setting