background image

                                                                                                K+R Performance Engineering, Inc. 

 

 
Rev 08-99 

 

PRO-CUBE

 

Ò

 

I

NSTALLATION AND 

O

PERATING 

M

ANUAL

 

 

Congratulations  on  your  purchase  of  the  most  advanced  combination  delay  box/timer  unit  available  for 
today’s precision drag racing.  The 

PRO-CUBE 

Ò

 

has been designed to give you unprecedented control of 

your  reaction  time  and  ET  with  a  host  of  standard  features,  plus  options  for  up  to  three  general  purpose 
timers, all in one super-compact unit that can be mounted almost anywhere.  The precision available with 
these timers makes them perfect for controlling a variety of equipment including throttle stops, shifters, and 
multi-stage  nitrous  systems.  You  should  read  and  understand  this  entire  manual,  including  the  warranty 
section beginning on page 8, before proceeding with installation. 

 
STANDARD FEATURES

 

 
Cross-Over: 

 

Allows you to release the transbrake switch on a slower opponent’s top bulb on a full 

open tree.  The delay time is automatically calculated from dial-in and delay values you enter. 

 
Second Hit: 

 

You  can  enter  a  separate  delay  for  hitting  the  tree  a  second  time.    It’s  the  same  as 

having two delay boxes in one.  This feature allows you to take two shots at the tree in long cross-
over situations.  You will launch on the faster of the two reactions. 

 

Bump-Down

 

Ò

This powerful feature allows you to improve late reactions by subtracting delay time 

after  releasing  the  transbrake  switch.    You  can  program  the  amount  of  time  to  subtract,  you  can 
bump-down  any  number  of  times,  and  you  can  use  it  for  either  one  or  both  hits  on  the  tree.    In 
addition, this feature can be used on Timer 1 during the run.  If you have a throttle stop connected to 
Timer 1, the Bump-Down feature will allow you to correct for track conditions such as tire spin by 
reducing the stop time. 

 

Flinch Protection 

Ò

Two different methods are provided for preventing red-light disqualification when you 

release the transbrake switch before the tree starts.

 

 
Run Info: 

 

If  you  use  either  the  second  hit  or  the 

Bump-Down

Ò

  feature,  information  will 

automatically be displayed to indicate the difference in your reaction times for double-hits, as well as 
the  number  of  times  you  bumped-down  your  reactions  and  the  number  of  times  TIMER  1  was  
bumped-down.  This allows you to determine what your reaction(s) and E.T. would have been had 
you not used these powerful features. 

 
Transbrake Output: 

High current output for use on all types of transmission brake, foot brake, and clutch 

release solenoids.  Handles up to 25 amp load. 

 
Line Lock Output: 

This  output  is  activated  and  released  simultaneously  with  the  transbrake  output  but 

includes  a  blocking  diode  to  prevent  back  feed  into  the  transbrake  circuit.    It  can  be  used  in  front 
wheel line lock applications or jumpered to the 

Pro-Stage

 

ä

 or one of the timer outputs acting as a 

“launch control” when connected to a compatible throttlestop.  Handles up to 2 amp load. 

 
Transbrake Lockout:  A  built-in  timer  prevents  activation  of  the  Transbrake  and  Line  Lock  outputs  for  a 

programmed amount of time after the transbrake releases.  This timer can be set from 0 to more than 
an hour.  Transbrake activation is automatically re-enabled when the timer completes. 

 

Содержание PRO-CUBE

Страница 1: ...you can use it for either one or both hits on the tree In addition this feature can be used on Timer 1 during the run If you have a throttle stop connected to Timer 1 the Bump Down feature will allow...

Страница 2: ...ave 2 stages 1 on off cycle each Timer 1 adjustable from 0 000 9 999 seconds timer 2 and 3 adjustable from 0 00 39 99 seconds SPECIFICATIONS Overall Dimensions H x W x D 4 3 x 4 7 x 2 95 Weight 1 3 lb...

Страница 3: ...TIMER 2 ON TIMER 2 OFF 5 0 0 6 0 0 TIMER 2 ON TIMER 2 OFF TIMER 3 ON TIMER 3 OFF INTERFACE DOUBLE HIT MODE in Fc d UAL 2 TRIGGER SWITCHES n OFF n OFF TIMER 1 MODE TIMER 2 MODE NORMALLY OFF MODE 0 0 10...

Страница 4: ...ing the switch again In this mode a known red light situation can only be prevented by pressing and holding the TRIGGER 1 switch until the bottom of your tree Your vehicle will launch instantly when t...

Страница 5: ...the transbrake to be reactivated after backing up from burnout for example The transbrake lockout time settings are independently set for Pro tree and for Full tree run programs OPERATION The Pro Sta...

Страница 6: ...can hit the PSTG BMP switch any number of times to reduce the delay and improve your reaction Each time you bump down the programmed amount of time is subtracted from either your first hit DELAY 1 or...

Страница 7: ...Release the switch near the bottom of your tree for instant launch Example 4 You re racing a Pro tree and equipped with a throttle stop You re in Pro tree run mode with times set in TIMER 1 to contro...

Страница 8: ...ressive spiral core wire set TECHNICAL SUPPORT Contact K R Performance Engineering Inc Telephone 423 614 7778 WARRANTY We at K R Performance Engineering Inc warrant to the original purchaser the produ...

Страница 9: ...of these goods This warranty shall not apply to any K R Performance Engineering Inc product or parts thereof which has been repaired or altered without K R Performance Engineering Inc s written consen...

Страница 10: ...US INJECTION SYSTEM FULL THROTTLE SWITCH TRIGGER 1 SWITCH TRIGGER 2 SWITCH LINE LOCK SWITCH PRO STAGE BUMP DOWN SWITCH CONNECT TO 12V FUSED OPTIONAL OPTIONAL OPTIONAL TWO STAGE RPM LIMITER TO IGNITION...

Страница 11: ...NSTALLATIONS ATTACH RUBBER GASKET TO PRO CUBE TO FILL GAP AND PREVENT METAL TO METAL CONTACT WITH DASH UNIT MUST FIT SNUG IN DASH OPENING DASH CUTOUT 5 1 x 4 1 0 5 RADIUS ORDER OUR INSTALLATION KIT FO...

Страница 12: ...Pro Cube K R Performance Engineering Inc 12...

Отзывы: