background image

42256_A

01-09-14

1

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, 
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.   All material copyright of Balboa Water Group.

spaTouch™ Menued Control Panels

Balboa Water Group BP Series Systems

User Interface and Programming Reference 

The spaTouch™ menued panel is compatible with all BP systems that already support the TP800 and/or the TP900. 

If this panel is used with a system that supports only the TP400 and/or TP600, many screens will work correctly, 
but the spa screen will not display correctly and may not control all of your equipment.

Set: 104°F

8:32 PM

Ozone

Filter 1

Spa

Scenes

Settings

High Range

102°F

Ready in Rest Mode

Heating

Содержание BP Series

Страница 1: ...a Water Group spaTouch Menued Control Panels Balboa Water Group BP Series Systems User Interface and Programming Reference The spaTouch menued panel is compatible with all BP systems that already supp...

Страница 2: ...features including Set Temperature adjustment can be accessed from this screen The actual water temperature and Set Temperature can be seen and the Set Temperature can be adjusted see page 4 Time of D...

Страница 3: ...t is selectable The menu selections on the right side of the screen can be selected Select one of these to enter a different screen with additional controls Most menu screens time out and revert to th...

Страница 4: ...other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group The Set Temperature Screen Set Set Temperature 101 F High Range Back Dec Inc Set Temperatur...

Страница 5: ...ent installed on a particular spa model so this screen may change depending on the installation The icon buttons are used to select and control individual devices Some devices like pumps may have more...

Страница 6: ...e labeled or not they always mean Save and Cancel They appear on most editing screens once you have changed the value on that screen If the screen times out due to no activity it will act like Cancel...

Страница 7: ...Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Page Up Down If an Up or Down button is shown and pressed when in a Menu List the list can be scrolled a page at a time The scroll ba...

Страница 8: ...pointing to the right go to another level in the menu Settings Back Temp Range Heat Mode Time of Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Dual Temperature Ranges High vs Low T...

Страница 9: ...until the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn th...

Страница 10: ...em on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not owing from the jets in the spa do not allow the pumps to continue to...

Страница 11: ...The speci c Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the eld Other device options may be available like Blower Light Mister etc Filtration and Oz...

Страница 12: ...e of Day Be sure to set the Time of Day Setting the time of day is important for determining ltration times and other background features Set Time will appear on the display if no time of day is set i...

Страница 13: ...t allow programming ltration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode detail...

Страница 14: ...Light Timer is OFF by default The settings can be edited the same way that Filter Cycles are edited see page 13 Speci c Buttons for Speci c Devices If the spa has an Auxiliary Panel s installed press...

Страница 15: ...event unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features...

Страница 16: ...ng any Scene line which has not yet been stored will simply turn off all spa devices Scenes Scene 1 Scene 2 Scene 3 Scene 4 Back Scene stored What are Scenes Scenes are stored combinations of equipmen...

Страница 17: ...s enabled so it may not appear This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular hot tub Fault Log The Fault Log is a record of the...

Страница 18: ...nd 24 hr display Reminders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time...

Страница 19: ...ystem Model Displays the Model Number of the System Current Setup Displays the currently selected Con guration Setup Number Con guration Signature Displays the checksum for the system con guration le...

Страница 20: ...oblem Forcing the GFCI Trip Test North America Only The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should trip within several seconds and the...

Страница 21: ...is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended...

Страница 22: ...it The spa is shut down for 15 min Reset this message to reset the heater start up See Flow Related Checks below The heater is dry M027 There is not enough water in the heater to start it The spa is...

Страница 23: ...ensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has fai...

Страница 24: ...Only May indicate an unsafe installation Contact your dealer or service organization Hot fault M035 A Pump Appears to have been Stuck ON when spa was last powered POWER DOWN THE SPA DO NOT ENTER THE...

Страница 25: ...ater chemistry with a test kit and adjust with the appropriate chemicals Clean the lter May appear on a regular schedule i e every 30 days Clean the lter media as instructed by the manufacturer See HO...

Страница 26: ...RCD will have a TEST and RESET button on it that allows a user to verify proper function Additional messages may appear on speci c systems Change the water May appear on a regular schedule i e every 9...

Страница 27: ...THE INSTRUCTION MANUAL s DEQUATE DRAINAGE MUST BE PROVIDED IF THE EQUIPMENT IS TO BE INSTALLED in a pit s OR USE ONLY WITHIN AN ENCLOSURE RATED 3 NCLOSURE s ONNECT ONLY TO A CIRCUIT PROTECTED BY A LAS...

Страница 28: ...18 Fault Log 17 Filter 2 filter cycle 11 13 Flow Related Checks 22 Freeze Protection 8 11 21 G GFCI 27 GFCI Test 17 20 H Heat Mode 9 High Range 8 Hold 17 I Information 19 L Language 18 Light Cycle 14...

Отзывы: